Description
Features:
- Polyplumb red underfloor heating panel for screeded floors can be permanently built into solid concrete or screeded floors.
- The heating pipe is simply slotted into the panel and then permanently covered by the screed.
- Suitable for all floor coverings, solid floor systems can incorporate 15mm or 18mm pipe.
- The floor panels form a simple grid for the quickest possible pipe laying and provide a precise guide to achieve the minimum bending radius.
- Panel castellations are set at exact centres and hold the pipe against movement when screeding.
- The floor panel holds the pipe above the insulation allowing full screed surround.
- Optimum screed depth is 65mm from the panel base, i.e. 40mm from the pipe top.
- Insulation below and at the edges of the floor screed is required by Building Regulations.
- Edge insulation also acts as an expansion joint.
Technical data:
- Solvent Weld – No
- Fire Rating (hrs) – 0