Description
By choosing Magby Euroclass Board you are choosing strength, security and durability combined with troubleless installation.
Features:
- Dimensional stability is achieved thanks to inorganic substances and reinforcement meshed used in a manufacture process.
- Designed to accept direct render to form external façades of commercial and domestic buildings using hybrid frame structures, and it’s suitable for timber and steel frame or modular systems.
- Carries multiple international certificates – able to last 90 min in a testing conditions.
- Magply provides extremely efficient substrate board for cementitious and acrylic render.
- Extremely low level of chloride provides stability and durability.
- Excellent fire, frost, moisture and impact resistance.
- Made especially for direct render applications.
- Suitable for steel frame and timber frame.
- Magnesium Oxide formulation.
- Environmental friendly.
Technical data:
- Brand – Magply
- Product Type – Euroclass A1 Non Combustible Board
- Appearance – Solid Flat Sheet Board
- Colour – White
- Odour – Odourless Change of State None
- Thickness – 6mm
- Width – 1200mm
- Length – 2400mm
- Weight per Board – 19kg (6.6kg/m²)
- Thermal Conductivity – 0.19W/mK
- Thermal Resistance – 0.032 m²K/W
- Melting point – 2400°C
- Density – 1100g/m³
- pH level – 7.5
- Solubility – Insoluble in Water
Standards & Certifications:
- Fire classification – Class 0 Euroclass EN13501
- Reaction to fire – Passed BS EN 1716
- Vapour resistance – 0.31 MNs/g ( EN ISO 12572)
- BS EN ISO 1182, BS EN 476 (PART 6&7), BS EN 594, BS EN 1364-1:2015, BS 476, EN 1365 – 1:2012, BS EN ISO 10140-2:2010
Please Note:
- Minimum 25mm batten fixed at maximum 600mm centres. Fixing set at 300mm centres, guidance must be taken from the architect or engineer.
- Boards should be mechanically fixed minimum 38mm for 9mm and 42mm for 12mm. Guidance should be taken for the architect or engineer.
- Minimum 25mm continuous cavity behind the board top to bottom finishing 150mm from ground level and 5mm from top soffit.
- The final installation drawing should always come from your structural engineer or architect.
- Boards should be staggered and always render on the course side of the board.
- A layer of DPC is recommended on the face of the batten behind the board.
- Ensure the board is free from all debris and dry before applying render.
- Always screw Magply at least 15mm in from the edge of the board.
- Air flow should be specific around windows and doors.






Reviews
There are no reviews yet.